1107200
Shadow VI User Manual
page 104
Appendix A
Excerpts from OSHA Regulations and
ANSI
Standards
Daily Tests in French and English
Extracts from ANSI B11.1-2009 8.6.3
Standards Requirements
Explanatory Information
8.6.3.18
The device shall not be affected by
ambient light or by light-source decay so that the
increase in response time or object sensitivity is
greater than the value used to calculate the
safety distance.
E8.6.3.18
Examples of ambient light are
associated with windows, light fixtures, skylights,
bay doors, or die lights.
8.6.3.19
All areas of entry to the point-of-
operation not protected by the presence-sensing
device shall be otherwise safeguarded.
E8.6.3.19
Usually the electro-optical presence-
sensing device is used in a manner that
provides a protected zone in front of the primary
work area with auxiliary devices or guards used
to protect secondary access areas.
In some cases, mirrors may be used in
conjunction with the device to provide two-,
three- or four-sided protection.
8.6.3.20
Press production systems with a
configuration that would allow an individual to
enter, pass through, and become clear of the
presence–sensing device sensing field shall not
be operated in the PSDI mode of operation.
E8.6.3.20
For PSDI applications see Clause 10.
8.6.3.21
When a device is used on a press
production system and the protection of the
operator is dependent upon the stopping action
of the press, a stopping-performance monitor
shall be required in conformance with 6.12. See
section 8.3.9 for exceptions.
Содержание Shadow VI
Страница 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Страница 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 159: ......