Shadow VI User Manual
1107200
Installation of Shadow VI-WPC Control Board Appendix C
page 121
shadow
VI
WINTRISS LIGHT CURTAIN
MAX RESPONSE TIME <40mS
INPUT POWER
115/230 VAC 1/4 A
50-60Hz MAX 20 VA
SOLID STATE OUTPUTS
MAX 20 mA/24VDC
SEE CONTROLLER BOARD FOR ITEM
& SERIAL NUMBERS
1-800-586-8324
®
Substitution of
components may
impair operator
safety.
La substitution
d’éléments constitutifs
peut compromettre la
sécurité d l’operateur.
!
WARNING AVERTISSEMENT
Figure C-1. Shadow VI - WPC Labels
"Daily tests" label (left), "Shadow VI" label showing response time (upper right),
“Warning” label (lower right)
ATTENTION
CAUTION
Perform these tests daily to make sure
the Light Curtain and the machine's
control system work properly. Also,
perform these tests after any
modification or maintenance to the
Light Curtain or the machine.
NOTE: Use an opaque 1 1/4" diameter
test bar for performing the daily tests.
1. Turn on power to the Light Curtain
and the machine. If the red and green
lights are on at the same time, clear the
Light Curtain to green state by
momentarily interrupting the sensing
field with a test bar.
2. If your Light Curtain has a Floating
Window, shut off the Floating Window
system. Make sure the Floating
Window indicator light goes off.
3. Interrupt the sensing field on the
receiver side by passing the test bar
from the top to the bottom of the
receiver lens cover. The red light
should come on while the bar is in the
sensing field.
4. Repeat step 3, passing the bar from
the top to the bottom of the transmitter
lens cover. Make sure the red light
comes on when the bar is in the
sensing field.
5. Start the machine and interrupt the
sensing field with the test bar. The red
indicator light on the receiver should
come on and the machine should
immediately stop. NOTE: When muting
is used, interrupting the Light Curtain
during the muted portion of the stroke
will NOT stop the machine.
6. Cycle the machine and make sure it
stops at the proper position and that the
machine's braking system is working
properly. If the machine does not brake
fast enough, adjust the braking system
or increase the Light Curtain's safety
distance.
7. If the machine or Light Curtain fails
any of these tests, DO NOT RUN THE
MACHINE. Notify the supervisor
immediately.
8. When using the Light Curtain with
mechanical power presses, all OSHA
Safety and Health Standards
(29 CFR 1910.217) must be met. DO
NOT USE THE LIGHT CURTAIN ON
F U L L R E V O L U T I O N C L U T C H
MACHINES.
LIGHT CURTAIN DAILY TESTS
Perform these tests daily to ensure the
Light Curtain and the machine's control
system work properly. These tests
should also be performed after any
modification or maintenance to the
Light Curtain or the machine.
Des essais doivent être effectués
chaque jour pour s'assurer que le
rideau de lumière et le système de
commande de la machine fonctionnent
comme il faut. Ces tests doivent
également être effectués après toute
modification ou tout entretien du rideau
de lumière ou de la machine.
C42254 Rev
Содержание Shadow VI
Страница 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Страница 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 159: ......