Chapter 1
Introduction to Shadow VI
Safety Light Curtain
OSHA and ANSI Compliance
Shadow complies with OSHA CFR 1910.212 "General Machine Guarding" and 1910.217
"Mechanical Power Presses", ANSI B11.1-2009 "Mechanical Power Presses", ANSI B11.19
"Performance Criteria for Safeguarding"; ANSI B11.20 "Manufacturing Systems/Cells"; and
ANSI/RIA 15.06 "Industrial Robots and Robot Systems".
These regulations require that a single component failure cannot jeopardize operator safety.
Critical components are duplicated and continually cross-checked during operation to
guarantee that a single component failure can never create an unsafe condition. Self-
checking circuitry detects the presence of any faults and signals the press to stop.
About Shadow VI
DANGER
!
INCORRECT INSTALLATION
•
Ensure that presses equipped with Shadow light curtains meet the requirements and
inspection procedures of OSHA regulation 1910.217 and ANSI standard B11.1-2009.
•
Ensure that other machinery or devices meet OSHA regulation 1910.212 for general
machine guarding and any other regulations that apply.
Failure to comply with these instructions will result in death or serious injury.
NOTICE
EXCERPTS FROM OSHA REGULATIONS AND ANSI STANDARDS
Excerpts from OSHA regulation 1910.217 and from the American National Standards Insti-
tute (ANSI) standards for safety devices are also included in Appendix A. ANSI is a fed-
eration of trade and professional organizations which sets standards for the industry based
upon a national consensus of manufacturers, scientists, technical and professional groups.
Shadow safety light curtains provide excellent protection. Once properly installed,
Shadow VI does not require additional adjustment, and no maintenance is required. You do
not have to worry about personnel forgetting to close gates or replace barriers.
The optic heads are constructed of rugged, heavy-gauge extruded aluminum (0.12-inch wall
thickness). These compact heads (2" x 2.85" cross-section) come in sizes ranging from 6
inches to 5 feet in height. The transmitter and receiver (see Figure 1-1) are optionally
available in explosion-proof enclosures.
Shadow also includes a control enclosure (Figure 1-2) to which
any-sized
receiver and
transmitter can be wired. No special settings are required. The control contains a power
supply, relay circuitry, and switch block assemblies where you can easily enable or disable
Shadow's options.
For added security, the control comes standard with an enclosure keylock and a reset
keyswitch. Simply turn the reset keyswitch to the right when resetting is required.
Содержание Shadow VI
Страница 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Страница 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 159: ......