1107200
Shadow VI User Manual
page 52
Chapter 2
Installation and Checkout
7. Leave a service loop at the control to allow for later adjustment of the conduit. Cut the
wires as necessary. Proceed to the next section "Connecting Stop Circuits to the
Control".
Do not connect wires to AC power source until you are done with all other
installation procedures.
Connecting Stop Circuits to the Control
DANGER
!
FULL REVOLUTION MECHANICAL POWER PRESSES AND OTHER MACHINES
CANNOT BE STOPPED IN MID-STROKE OR MID-CYCLE
•
DO NOT use Shadow safety light curtains on full-revolution clutched machinery or other
equipment that cannot be stopped at any point in its stroke or cycle.
•
Use Shadow safety light curtains only on machinery that can be stopped at any point in its
stroke or cycle.
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
PRESS MAY CONTINUE TO MOVE AFTER INTRUSION
•
Ensure that Shadow is wired to the emergency stop circuitry of the press.
•
Ensure that any stop initiated by the light curtain is an immediate stop, one that occurs
immediately after the stop signal is sent to the machinery. If the light curtain is not correctly
wired in this way, the press may continue its stroke after an intrusion is detected.(
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
STOP CIRCUITS NON-OPERATIVE IN SOME MODES
Wire the light curtain in series with your press control circuit so the stop signal from the light
curtain stops the machine immediately in all modes of operation, including inch.
Failure to comply with these instructions will result in death or serious injury.
WARNING
!
ELECTRIC SHOCK HAZARD
•
Ensure that the power source is off before you make any wiring connections.
•
Disconnect power from the machinery it is connected to before making any wiring
connections. This includes disconnecting power to the machine control and motor.
•
Ensure that all procedures are performed by qualified personnel.
Failure to comply with these instructions could result in death or serious injury.
Содержание Shadow VI
Страница 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Страница 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 159: ......