Excerpts from OSHA Regulations and
Appendix A
page 109
ANSI Standards
Daily Tests in French and English
Extracts from ANSI B11.19-2003 8.3
Standards Requirements
Explanatory Information
The device shall be installed such that it does
not create additional hazards.
Some installation hazards include, but are not
limited to:
pinch point hazards created by interference between
the device and moving members of the machine;
tripping hazards;
electrical shock hazards;
overhead or other "strike against" hazards;
thermal hazards.
Where such conditions can exist, additional
safeguarding may be required.
8.3.2.2
The presence-sensing device shall be
installed at a location so that the effective
sensing field prevents individuals from reaching
the hazard(s) during the hazardous portion of
the machine cycle.
E8.3.2.2
The safety distance calculation is
dependent upon the:
total response time of the device as stated by the
safeguarding supplier;
response time of the interface;
response time of the control system;
time it takes the machine to stop hazardous motion;
and
depth penetration factor of the device.
See Annex D for the formula(e) to calculate the
safety distance.
Radio frequency devices have sensing fields
that can vary due to:
antenna(e) design;
effects of adjacent machinery and equipment;
field sensitivity adjustments; and
environmental factors (such as humidity or
temperature).
Before the machine is used for production
purposes, the RF device should be checked to
ensure that the effective field protects
individuals at the safety distance.
Содержание Shadow VI
Страница 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Страница 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 158: ......
Страница 159: ......