TH180 Programmer’s Guide
139
<Function 48> GS ( L pL pH m f n
[Format]
1DH, 28H, 4CH, pL, pH, m, fn,
[Valid limits]
(pL+pH×256)=2
(pL=2, pH=0)
m=48
fn=0, 48
[Function] (1) It transmits the total capacity of the NV graphics area in byte counts.
Hex
Decimal
Data number
Header
37H
55
1 byte
Identification
30H
48
1 byte
Data
30H ~ 39H
48 ~57
1~8 byte
N U L
00H
0
1 byte
(2) The total capacity is expressed in decimal, changes to character code and transmits from the top
digit.
The data number becomes a changeable length.
It is possible to designate the total definition area from one of the [384K, 448K, 512K,
576K]bytes from GS (E. The initial value is 384 byte.
<Function 50> GS ( L pL pH m f n
[Format]
1DH, 28H, 4CH, pL, pH, m, fn
[Valid limits]
(pL+pH×256)=2
(pL=2, pH=0)
m=48
fn=2, 50
[Function] (1) The process of <Function 112> prints the print buffer stored in the graphics data.
(2) It executes the paper-feed equivalent to the dot count in the Y-direction graphics stored in the printer
buffer.
<Function 51> GS ( L pL pH m fn
[Format]
1DH, 28H, 4CH, pL, pH, m, fn,
[Valid limits]
(pL+pH×256)=2
(pL=2, pH=0)
m=48
fn=3, 51
[Function] (1) The NV graphics area transmits the remaining quantity (byte count of the unused area).
Hex
Decimal
Data number
Header
37H
55
1 byte
Identification
31H
49
1 byte
Data
30H ~ 39H
48~57
1~8 bytes
N U L
00H
0
1 byte
(2) The remaining capacity quantity is expressed in decimal, changes to character code and transmits
from the top digit.
The data number becomes a changeable length.
Содержание TH180
Страница 1: ...TH180 Thermal Printer Programmer s Guide Edition November 2012 ...
Страница 10: ...TH180 Programmer s Guide 5 Code Tables Page 0 PC437 ...
Страница 11: ...TH180 Programmer s Guide 6 Page 1 Katakana ...
Страница 12: ...TH180 Programmer s Guide 7 Page 2 PC850 ...
Страница 13: ...TH180 Programmer s Guide 8 Page 3 PC860 ...
Страница 14: ...TH180 Programmer s Guide 9 Page 4 PC863 ...
Страница 15: ...TH180 Programmer s Guide 10 Page 5 PC865 ...
Страница 16: ...TH180 Programmer s Guide 11 Page 16 WPC1252 ...
Страница 17: ...TH180 Programmer s Guide 12 Page 17 PC866 ...
Страница 18: ...TH180 Programmer s Guide 13 Page 18 PC852 ...
Страница 19: ...TH180 Programmer s Guide 14 Page 19 PC858 ...
Страница 20: ...TH180 Programmer s Guide 15 Page 254 MIK ...
Страница 21: ...TH180 Programmer s Guide 16 Page 255 Blank Page ...
Страница 22: ...TH180 Programmer s Guide 17 Page 8 PC857 ...
Страница 23: ...TH180 Programmer s Guide 18 Page 26 Thai code 18 ...
Страница 24: ...TH180 Programmer s Guide 19 Page 40 PC864 ...
Страница 25: ...TH180 Programmer s Guide 20 Page 249 PC851 ...
Страница 26: ...TH180 Programmer s Guide 21 Page 250 PC869 ...
Страница 27: ...TH180 Programmer s Guide 22 Page 251 ISO8859 2 ...
Страница 28: ...TH180 Programmer s Guide 23 Page 252 ISO8859 7 ...
Страница 29: ...TH180 Programmer s Guide 24 Page 253 PC866 Type 2 ...
Страница 162: ...Wincor Nixdorf International GmbH 2012 D 33094 Paderborn ...