7.0. Operation
7.5. Operating the precise overseeding unit
7.5.6. Automatic dosing
With automatic dispensing, the speed of the cellular rotor is calculated according to the following values:
•
Speed
•
Output rate
•
Qty. adaptation
•
Working width
•
Calibration value of the spreading material
The calibration value can be stored in a calibration test, see Chapter 7.5.5.4, "Calibration test" .
The output rate and product can be set directly, see Chapter 7.5..5, "General setting possibilities and displays" .
Starting automatic dosing:
The automatic dosing system will only start if there is a speed signal, a linkage signal is being output and there is
material in the hopper, see Chapter 7.5.5.11, "Error memory" .
1. Press the Start/Stop key.
The blower will start, the blue blower LED and the
blue LED in the Start/Stop key will flash until the
set speed has been reached, see Chapter
7.5.5.14, "Blower".
The LED in the Start/Stop key will turn orange when
the blower speed has been reached.
2. Only press the "Start/Stop" when the speed is
greater than 2 km/h and the hydraulics are lowered.
The dosing system will start.
The blue LED in the Start/Stop key will be lit.
Warning!
Risk of injury!
Make sure that no other persons or animals are in the danger zone during operation.
START/STOP