All information, illustrations and technical specifications in these operating instructions are based on the latest information available at the time of
publication. We reserve the right to make design changes at any time without prior notification.
89
8.0 Maintenance
8.10. Maintaining and cleaning the precise overseeding unit
8.10.2. Spreading material hopper
Advice
Clean the hopper, rotary feeder shafts, agitator and blower in dry condition!
Never clean the spreader with a high-pressure cleaner or highly acidic cleaning agents. Do not use
any greases or oils. Note the instructions from the manufacturers
Cleaning the hopper
Clean the hopper and spreader at the end of the season. The hopper can be nearly
completely emptied by means of the residual discharge, see 7.5.5.10 "Residual
discharge". If there are larger quantities of spreading material or mal- functions in
operation, the hopper can also be emptied via a hatch, see Emptying the hopper through
the residual discharge hatch.
All residues that build up during cleaning of the spreader must be collected and disposed
of ac- cording to the regulations valid in the particular country.
Attention
:
Risk of injury during maintenance work.
This can lead to crushing due to inadvertent start-up of the machine or short
circuit.
•
Disconnect the electrical power supply before starting maintenance, repair
and cleaning work.
•
Wear appropriate working and protective clothing during all work
.
1.
Empty the hopper if necessary, see Emptying the hopper.
2.
Remove the agitator and clean it, see Cleaning the agitator.
3.
Clean the hopper, agitator and spreader in dry condition or, if required, with a damp
cloth and suitable cleaning agent.
4.
Reassemble the spreader.
Emptying the hopper through the residual
dis- charge hatch
The hopper can be emptied through the hatch (1).
1.
Switch off the Saateinheit.
2.
Place a collecting container under the hatch (1).
3.
Unscrew the knurled screws (2) and open the
hatch.
4.
After emptying, close the hatch (1) again