All information, illustrations and technical specifications in these operating instructions are based on the latest information available at the time of
publication. We reserve the right to make design changes at any time without prior notification.
94
8.0 Maintenance
8.10. Maintaining and cleaning the precise overseeding unit
8.10.7. Install / Remove emty indicator
Removal
1. Strip and expose the cable.
2. Undo the lock nut (2).
3. Unscrew the sensor (3) from the housing (1).
Installation
1. Screw the new sensor (3) into the housing (1)
until you feel resistance.
Only tighten the sensor by hand, risk of
damage.
2. Tighten the lock nut (2).
3. Route and connect the cable.
8.10.8. Storage and disposal
Storage
Before storing the spreader, empty it completely and clean it,
see 8.10.2 "Spreading material hopper".
The spreader should be stored in a
dry place,
without exposure to direct sunlight,
at a temperature range from -10 to +50 °C.
Disposal
Dispose of the spreader according to local regulations and laws