All information, illustrations and technical specifications in these operating instructions are based on the latest information available at the time of publication.
We reserve the right to make design changes at any time without prior notification.
73
7.0. Operation
7.5. Operating the precise overseeding unit
7.5.10. Troubleshooting
No signal from the wheel sen-
sor
•
Check the distance between the sensor and wheel nuts and adjust if nec-
essary. Distance should be less than or equal to 4 mm.
•
Check the wheel sensor/control panel plug connection.
•
Check the counting points.
•
Check the cables.
No signal from the linkage mag-
netic sensor
•
Distance between the sensor and magnet too large.
•
Note the installation direction of the sensor, see 2.4.2.
„
VGM Magnet
”
.
•
Check the cables.
Output rate excessive/insuffi-
cient
•
Perform a calibration test, enter the correct value and confirm.
•
Check the quantity adaptation.
•
Check the cellular rotor for contamination.
•
Check the brushes for signs of damage and contamination. see 8.10.5.
"Brushes".