All information, illustrations and technical specifications in these operating instructions are based on the latest information available at the time of publication.
We reserve the right to make design changes at any time without prior notification.
72
7.0. Operation
7.5. Operating the precise overseeding unit
7.5.9. Error message
Message on the display
Error No.
Explanation
Cellular rotor blocked
1
•
Check cellular rotor shaft for foreign bodies and
remove blockage
Cellular rotor not responding
2
•
The control cable for the spreader is not connected
to the control panel
•
Check the control cable for damage
•
Check the connection cable for the cellular rotor drive
unit
•
Check the plug on the control cable for damage
Blower blocked
3
•
Check the blower for blockages
Excess voltage
4
•
Max. voltage supply 15.5 V
Inadequate voltage
5
•
Check voltage supply (min. 12.5 V)
•
Have you used our original 6 mm² battery cable?
Travel speed too high
7
•
Maximum cellular rotor speed reached
•
Reduced travel speed or use a larger cellular rotor
Hopper empty
8
•
Residual quantity (approx. 2 l) in the hopper
Speed signal missing
9
•
No speed signal detected
•
Faulty contact or cable break on speed sensors
Overheating
10
•
Allow the control unit to cool
•
Check the ventilation openings on the side covers to
ensure they are clear
•
Keep the control unit out of direct sunlight
•
Check the power supply, is sufficient voltage being
supplied (min. 12.5 V)