Logical Command and Speed Reference
CFW300 | 7-5
7
E.P.:
electronic potentiometer; refer to
Section 12.5 DIGITAL INPUTS on page 12-11.
Multispeed:
refer to
Section 12.5 DIGITAL INPUTS on page 12-11.
AIx > 0:
the negative values of the AIx reference are zeroed.
CO / DN / DP:
CANopen, DeviceNet or Profibus DP Interface.
P223 - FORWARD/REVERSE Selection - LOCAL Situation
P226 - FORWARD/REVERSE Selection - REMOTE Situation
Adjustable
Range:
0 = FORWARD
1 = REVERSE
2 and 3 = Not Used
4 = DIx
5 = Serial/USB (FWD)
6 = Serial/USB (REV)
7 and 8 = Not Used
9 = CO/DN/DP (FWD)
10 = CO/DN/DP (REV)
11 = Not Used
12 = SoftPLC
Factory
Setting:
P223 = 0
P226 = 4
Properties:
cfg
Description:
They define the origin source for the "Direction of Rotation" command in the Local and Remote situation, where:
FWD:
Means Forward.
REW:
Means Reverse.
DIx:
refer to
Section 12.5 DIGITAL INPUTS on page 12-11
CO / DN / DP:
CANopen, DeviceNet or Profibus DP Interface.
P224 - Run / Stop Selection - LOCAL Situation
P227 - Run / Stop Selection - REMOTE Situation
Adjustable
Range:
0 = HMI Keys
1 = DIx
2 = Serial/USB
3 = Not Used
4 = CO/DN/DP
5 = SoftPLC
Factory
Setting:
P224 = 0
P227 = 1
Properties:
cfg
Description:
These parameters define the origin source for the "Run/Stop" command in the Local and Remote situation.
This command corresponds to the functions implemented in any of the command sources able to enable the
motor movement, that is, General Enable, Ramp Enable, Forward Run, Reverse Run, Start, etc.
Содержание CFW300 V1.3X
Страница 2: ......
Страница 8: ...Contents...
Страница 46: ...Identification of the Inverter Model and Accessories 6 4 CFW300 6...
Страница 60: ...Logical Command and Speed Reference 7 14 CFW300 7...
Страница 72: ...V f Scalar Control 9 10 CFW300 9...
Страница 80: ...VVW Vector Control 10 8 CFW300 10...
Страница 116: ...Digital and Analog Inputs and Outputs 12 24 CFW300 12...
Страница 132: ...Reading Parameters 15 6 CFW300 15...