Digital and Analog Inputs and Outputs
12-16 | CFW300
12
f) DIRECTION OF ROTATION
If the DIx is Inactive, the Direction of Rotation is Forward, otherwise, the direction of rotation will be REVERSE.
DIx
Time
Time
Inactive
Forward
Reverse
Active
Output
frequency
Figure 12.10:
Example of the Direction of Rotation function
g) LOCAL / REMOTO
If DIx is inactive, the Local command is selected, reverse the Remote command is selected.
h) JOG
The JOG command is the combination of the Run/Stop command with a speed reference via parameter P122.
DIx -
Run/Stop
DIx -
General Enable
Time
Time
Time
Inactive
Inactive
Active
Active
Output
frequency
JOG frequency
(P122)
Acceleration
ramp
Deceleration
ramp
Time
Active
Inactive
DIx -
JOG
Figure 12.11:
Example of the JOG function
Содержание CFW300 V1.3X
Страница 2: ......
Страница 8: ...Contents...
Страница 46: ...Identification of the Inverter Model and Accessories 6 4 CFW300 6...
Страница 60: ...Logical Command and Speed Reference 7 14 CFW300 7...
Страница 72: ...V f Scalar Control 9 10 CFW300 9...
Страница 80: ...VVW Vector Control 10 8 CFW300 10...
Страница 116: ...Digital and Analog Inputs and Outputs 12 24 CFW300 12...
Страница 132: ...Reading Parameters 15 6 CFW300 15...