Quick Reference of Parameters, Alarms and Faults
0-14 | CFW300
Param.
Description
Adjustable Range
Factory Setting
Prop.
Page
P930
Automatic Adjustment of the PID
Controller Setpoint
0 = P911 inactive and P918
inactive
1 = P911 active and P918 inactive
2 = P911 inactive and P918 active
3 = P911 active and P918 active
0
P931
Proportional Gain
0.00 to 99.99
1.00
P932
Integral Gain
0.00 to 99.99
5.00
P933
Derivative Gain
0.00 to 99.99
0.00
P934
PID Controller Sampling Period
0.050 to 9.999 s
0.100 s
cfg
P935
Filter for the PID Controller Control
Setpoint
0.000 to 9.999 s
0.150 s
P936
Deviation of the Control Process
Variable to Wake Up
-9999 to 9999 [SPLC Eng. Un.]
30
P937
Time to Wake Up
0 to 9999 s
5 s
P938
Motor Speed to activate the Sleep
Mode
0.0 to 400.0 Hz
0.0 Hz
P939
Time to activate de Sleep Mode
0 to 9999 s
10 s
(*)
Only available when some IO expansion accessory (CFW300-IOAR, CFW300-IODR, CFW300-IOADR or CFW300-IOAENC) is present (connected). For
further information, refer to the respective accessory guide.
(**)
Only available when some communication accessory (CFW300-CBLT, CFW300-CCAN or CFW300-CPDP) is present (connected). For further information,
refer to the respective accessory guide.
ro = read only parameter.
V/f = parameter available in V/f mode.
cfg = configuration parameter, value can only be changed with the motor stopped.
V VW = parameter available in V VW mode.
Содержание CFW300 V1.3X
Страница 2: ......
Страница 8: ...Contents...
Страница 46: ...Identification of the Inverter Model and Accessories 6 4 CFW300 6...
Страница 60: ...Logical Command and Speed Reference 7 14 CFW300 7...
Страница 72: ...V f Scalar Control 9 10 CFW300 9...
Страница 80: ...VVW Vector Control 10 8 CFW300 10...
Страница 116: ...Digital and Analog Inputs and Outputs 12 24 CFW300 12...
Страница 132: ...Reading Parameters 15 6 CFW300 15...