0
Quick Reference of Parameters, Alarms and Faults
CFW300 | 0-1
QUICK REFERENCE OF PARAMETERS, ALARMS AND FAULTS
Param.
Description
Adjustable Range
Factory Setting
Prop.
Page
P000
Access to Parameters
0 to 9999
1
P001
Speed Reference
0 to 9999
ro
P002
Output Speed (Motor)
0 to 9999
ro
P003
Motor Current
0.0 to 40.0 A
ro
P004
DC Link Voltage (Ud)
0 to 524 V
ro
P005
Output Frequency (Motor)
0.0 to 400.0 Hz
ro
P006
Inverter Status
0 = Ready
1 = Run
2 = Undervoltage
3 = Fault
4 = Self-Tuning
5 = Configuration
6 = DC Braking
7 = Reserved
8 = Fire Mode
ro
P007
Output Voltage
0 to 240 V
ro
P009
Motor Torque
-200.0 to 200.0 %
ro, VVW
P011
Output Cos
φ
-1.00 to 1.00
ro
P012
DI8 to DI1 Status
0 to FF (hexa)
Bit 0 = DI1
Bit 1 = DI2
Bit 2 = DI3
Bit 3 = DI4
Bit 4 = DI5
Bit 5 = DI6
Bit 6 = DI7
Bit 7 = DI8
ro
P013
DO4 to DO1 Status
0 to F (hexa)
Bit 0 = DO1
Bit 1 = DO2
Bit 2 = DO3
Bit 3 = DO4
ro
P014
(*)
AO1 Value
0.0 to 100.0 %
ro
P015
(*)
AO2 Value
0.0 to 100.0 %
ro
P018
AI1 Value
-100.0 to 100.0 %
ro
P019
(*)
AI2 Value
-100.0 to 100.0 %
ro
P022
FI Value in Hz
1 to 3000 Hz
ro
P023
Main SW Version
0.00 to 99.99
ro
P024
(*)
IO Acces. SW Version
0.00 to 99.99
ro
P025
(**)
Comm. Acces. SW Version
0.00 to 99.99
ro
P027
Config. Acces. IO
0 = Without Accessory
1 = CFW300-IOAR
2 = CFW300-IODR
3 = CFW300-IOADR
4 = CFW300-IOAENC
5 = Reserved
6 = CFW300-IODF
7 to 10 = Reserved
ro
P028
Config. Comm. Acces.
0 = Without Accessory
1 = CFW300-HMIR
2 = CFW300-CBLT
3 = CFW300-CCAN
4 = CFW300-CPDP
5 = Reserved
6 = CFW300-IODF
7 to 10 = Reserved
ro
Содержание CFW300 V1.3X
Страница 2: ......
Страница 8: ...Contents...
Страница 46: ...Identification of the Inverter Model and Accessories 6 4 CFW300 6...
Страница 60: ...Logical Command and Speed Reference 7 14 CFW300 7...
Страница 72: ...V f Scalar Control 9 10 CFW300 9...
Страница 80: ...VVW Vector Control 10 8 CFW300 10...
Страница 116: ...Digital and Analog Inputs and Outputs 12 24 CFW300 12...
Страница 132: ...Reading Parameters 15 6 CFW300 15...