Dynamic Braking
13-2 | CFW300
13
F022 - overvoltage
Dynamic braking actuation
DC Link Voltage (U
d
) (P004)
Time
Time
Braking resistor
voltage (DB)
P0153
Rated U
d
U
d
U
d
Figure 13.1:
Dynamic Braking actuation curve
Steps to enable the Dynamic Braking.
Connect the braking resistor. Refer to item 3.2.3.2 Dynamic Braking of the CFW300 user's manual.
Set P151 at the maximum value: (According to inverter model) to prevent the activation of the DC voltage
regulation before the Dynamic Braking.
DANGER!
Be sure the inverter is OFF and disconnected before handling the electric connections and read
carefully the installation instructions of the CFW300 user's manual.