Use in the field
173
These failures are probably caused by one of the following:
•
a hard object is blocking the agitator,
•
a hard object or a large piece of fertiliser is (partially) blocking the
supply from flowing to the agitator,
•
a hard object or a large piece of fertiliser is (partially) blocking
fertiliser from flowing through the dosing opening or discharge
bushing,
•
crushed and/or damp fertiliser forms an encrusted layer beneath
the agitator and blocks the flow through the dosing openings,
•
a lump of damp fertiliser has formed in the discharge bushing and
is blocking flow from the discharge bushing opening. This happens
especially when the spreader has not been thoroughly cleaned
after it was last used.
I
NDICATION
Most types of fertilisers attract water and can thereby form large
chunks. These chunks can block the spreader or distort the spreading
pattern.
•
When working under moist conditions, use a hopper cover that
closes well.
•
Do not spread without a hopper cover under moist conditions.
•
Never leave the fertiliser for a long period of time in the spreader.
Chunks can also be formed through moisture in the air.
•
Always clean the spreader well after use, including the dosing
openings and the discharge bushings.
Procedure
Handle with care
Cautiously approach the machine and handle with care. There could
be hot or live parts! Bodily injury may result.
To find the cause of the failure or stoppage and solve it as far as
possible, proceed as follows.
Disconnect the PTO shaft immediately!
Switch off the electronic control system.
Switch the tractor off, remove the key from the ignition and engage
the handbrake of the tractor.
I
NDICATION
Do not place the machine on the ground. Placing a filled machine on
the ground damages the structure!