3-22
TM-500 User’s Guide
The Setup Screens
D292144.6.fm
5. Place Settings
Place Position X
indicates the X Axis (left/right) place posi-
tion. This is the position the pick head will move to when plac-
ing a part in the
Output Module
.
Place Position Z
indicates the Z Axis (up/down) place posi-
tion. This is the position the head nozzle will move to when
placing a part in the
Output Module
.
Note:
Place Position X
and
Z
values can be entered
by manually moving the head and nozzle to the
desired positions. Once the nozzle is positioned, drag
and drop the
Current X
and
Current Z
values listed at
the bottom of the screen into the corresponding boxes
or press the
Teach Place Position
button.
Blow Off Time
is the amount of time in milliseconds that the nozzle will activate the blow-off
pressure to place a part in the
Output Module
.
The
Move To Place
button moves the pick head to the preset
Output Module
place position.
The
Place Part
button moves the head from its current location and places a part into the pro-
grammed place position.
The
Reject Part
button moves the head from its current location and places a part into the reject
position. The reject location is the
Reject Bin
unless specified in the
Tray Tab
to be
Rotate 180
or
Reject Tray
. (See
Tray Setup
section for details.)
6. Nozzle Settings
Speed
is the velocity at which the nozzle extends or retracts.
It can be set between 1-100.
Acceleration
is how rapidly the nozzle will accelerate to
reach
Nozzle Speed
. It can be set between 1-100. The lower
the value of this setting, the more gradual the acceleration will
be.
Jog Step
sets the distance in millimeters the nozzle will move
up or down each time a
Jog
button is pressed.
The
Nozzle
Jog
Controls
in the
Nozzle Settings
section jog
the head up or down along the Z Axis.
Содержание TM-500
Страница 2: ...European Representative QNET BV Hommerterweg 286 6436 AM Amstenrade The Netherlands...
Страница 17: ...Contact Information D292144 2 fm xiv...
Страница 21: ...Table of Contents D292144 3a fm...
Страница 47: ...2 14 TM 500 User s Guide Dual Tray Feeder Input Output Module D292144 5 fm...
Страница 83: ...3 36 TM 500 User s Guide The Setup Screens D292144 6 fm...
Страница 187: ...7 14 TM 500 User s Guide Ethernet Networks D292144 10 fm...
Страница 254: ...751 Summit Avenue Mankato MN 56001 507 387 2039 FAX 507 387 2257 www vtekusa com Email info vtekusa com...