6-18
TM-500 User’s Guide
Adjusting Seal Quality
D292144.9.fm
Adjusting Seal Quality
Heat Seal Adjustments
If a
Peel Force Test
determines the
Heat Sealer
is not generating a satisfactory seal, try one of
the adjustments below to improve seal strength.
Heat Seal Shoe Temperature
The
Temperature Controller
displays the actual temperature in
red
on the left and the set point in
green
on the right.
Increase or decrease the temperature of the sealer shoes. The
inside and outside seals have independent temperature control-
lers. Simply press the up or down buttons on the controllers to
adjust the target temperatures they maintain. Under normal con-
ditions and materials, changing the temperatures should suffice.
The TM-500 accommodates a wide range of carrier tapes and
cover tapes. Settings may vary from one tape product to another.
The suggested starting point is
120 degrees
.
Note:
Generally, it is best practice to adjust the temperature to achieve the desired peel
force. For additional information on adjusting the
Temperature Controller
, see
Appendix
A: Sensors
.
Seal Pressure
This control is located on the front of the
Taper
. It controls
the amount of force applied when the sealer shoes drop.
Turning the
Seal Pressure
control clockwise will increase
the pressure, while turning it counter-clockwise will
decrease the pressure.
Increase or decrease the air pressure supplied to the pneu-
matic cylinders that actuate the sealer. The recommended
operating range is 40-100 psi.
Dwell Time
Increase or decrease the dwell time (The amount of time the
sealer spends in contact with the cover tape)..This is set in
the HMI’s
Taper Settings Tab
in the
Sealer Settings
section
Note:
The dwell time affects the throughput of the
taper.
The recommended
Dwell Time
is 400 ms
.
Содержание TM-500
Страница 2: ...European Representative QNET BV Hommerterweg 286 6436 AM Amstenrade The Netherlands...
Страница 17: ...Contact Information D292144 2 fm xiv...
Страница 21: ...Table of Contents D292144 3a fm...
Страница 47: ...2 14 TM 500 User s Guide Dual Tray Feeder Input Output Module D292144 5 fm...
Страница 83: ...3 36 TM 500 User s Guide The Setup Screens D292144 6 fm...
Страница 187: ...7 14 TM 500 User s Guide Ethernet Networks D292144 10 fm...
Страница 254: ...751 Summit Avenue Mankato MN 56001 507 387 2039 FAX 507 387 2257 www vtekusa com Email info vtekusa com...