![V-TEK TM-500 Скачать руководство пользователя страница 171](http://html2.mh-extra.com/html/v-tek/tm-500/tm-500_user-manual_3085677171.webp)
6-22
TM-500 User’s Guide
Sensor Adjustments
D292144.9.fm
1.
Loosen the (2) screws on the
Carrier Tape
Reel Arm
so the
Carrier Low Sensor Mount
can be adjusted.
2.
The
Carrier Tape Sensor Rod
has one end
which rests on top of the carrier tape in the
Carrier Tape Reel so sense how full the reel
is. The other end is positioned in between the
two prongs of the Sensor.
Manually raise the
Sensor Rod
so the end
that is touching the tape in the
Carrier Tape
Reel
is positioned at the minimum level of
Carrier Tape that will be required to complete
the job.
3.
Move
the
Carrier Low Sensor Mount
so the
other end of the
Sensor Rod
is positioned
between the prongs of the Sensor.
4.
Tighten the (2) Sensor Mount screws and
release the
Sensor Rod
.
The
Carrier Low Sensor
is now ready for operation.
If the operator attempts to run a job when the carrier
tape is low, operation will stop, a beep will sound and
an error message will appear on the HMI.
Sensor
Rod
Содержание TM-500
Страница 2: ...European Representative QNET BV Hommerterweg 286 6436 AM Amstenrade The Netherlands...
Страница 17: ...Contact Information D292144 2 fm xiv...
Страница 21: ...Table of Contents D292144 3a fm...
Страница 47: ...2 14 TM 500 User s Guide Dual Tray Feeder Input Output Module D292144 5 fm...
Страница 83: ...3 36 TM 500 User s Guide The Setup Screens D292144 6 fm...
Страница 187: ...7 14 TM 500 User s Guide Ethernet Networks D292144 10 fm...
Страница 254: ...751 Summit Avenue Mankato MN 56001 507 387 2039 FAX 507 387 2257 www vtekusa com Email info vtekusa com...