6-20
TM-500 User’s Guide
Sensor Adjustments
D292144.9.fm
Sensor Adjustments
Adjusting the Low Cover Sensor
The
Low Cover Sensor
is one of five sensor options that are included with the standard TM-500.
It alerts the operator at the beginning of a job if there is not enough cover tape loaded on the
Cover Tape Reel
to complete the job.
Note:
The
Low Cover Sensor
should be enabled if the
Taper Output Module
is being
used.
Loosen the screws on the
Cover Tape Low Sensor
to
adjust it’s position. It should rest so the sensor light is
positioned at the minimum level of cover tape required
to complete a job.
If sensor sensitivity needs to be fine tuned, adjust the
amplifiers at the base of the
Cover Tape Arm
. For more
information on the sensor/amplifier, refer to
Appendix
A: Sensors
No further setup is required. The
Low Cover Sensor
is
ready to operate.