Adjusting Nozzle Vacuum Sensors
Chapter 6: Troubleshooting
6-15
Adjusting Nozzle Vacuum Sensors
The TM-500’s
Nozzle Vacuum Sensor
is setup before the machine is shipped. It may occasion-
ally require adjustment depending on vacuum sensitivity and the type of part that is being pro-
cessed.
If the TM-500 places “empty” pockets (i.e. places as though it held a part when it did not) or
returns a picking part error when it picked a part, the vacuum sensor’s threshold point probably
needs to be adjusted.
Vacuum Sensor Settings
1.
Close the enclosure doors, then open the
Head Setup Tab
.
2.
Press the
Pick Part
button to activate vacuum and pick a
part. Observe the vacuum sensor indicator which is located
on the
Pick & Place Head
above the nozzles The numbers
should be lit in
green
with components on the nozzle and
red
if components are not.
3.
If the sensors require adjustment, Press the blue
Set
button
once. The sensor will alternately flash
P_1
and the current
value.
4.
Use the
Up/Down Arrow Keys
to adjust the sensor as needed
with components both on and off of the nozzles..
5.
Press the blue
Set
button again to exit back to normal operation.
Содержание TM-500
Страница 2: ...European Representative QNET BV Hommerterweg 286 6436 AM Amstenrade The Netherlands...
Страница 17: ...Contact Information D292144 2 fm xiv...
Страница 21: ...Table of Contents D292144 3a fm...
Страница 47: ...2 14 TM 500 User s Guide Dual Tray Feeder Input Output Module D292144 5 fm...
Страница 83: ...3 36 TM 500 User s Guide The Setup Screens D292144 6 fm...
Страница 187: ...7 14 TM 500 User s Guide Ethernet Networks D292144 10 fm...
Страница 254: ...751 Summit Avenue Mankato MN 56001 507 387 2039 FAX 507 387 2257 www vtekusa com Email info vtekusa com...