Setup Pick Head
1.
Open the
Head Tab
on the HMI.
2.
Press
Move To Pick
, then press
Pick Part.
Observe the
vacuum sensor which is located on top of the head to see if it is
set correctly for the current part. The numbers should be lit in
green
with components on the nozzle and
red
if components
are not.
If the sensors require adjustment, increase or decrease the
test levels with the up and down buttons. Adjust them as needed with components
both on and off of the nozzles.
Note:
See the
Chapter 6: Troubleshooting
for vacuum sensor adjustment proce-
dures.
3.
Adjust the nozzle size if needed.
Note:
See the
Chapter 4: Machine Setup
for nozzle change procedures.