4-20
TM-500 User’s Guide
Taper Setup
D292144.7.fm
SEALER SETUP
A.
Inside Heat Seal Shoe Temperature Control
B.
Outside Heat Seal Shoe Temperature Control
C.
Heat Shoes - Seal Pressure Control
D.
Heat Shoes - Seal Pressure Gauge
Heat Sealer Setup
1.
Turn the heat sealer on and set the temperature
controls for
120 degrees
.
Note:
The TM-500 accommodates a wide range
of carrier tapes and cover tapes. Settings may
vary from one tape product to another.
The suggested starting point is
120 degrees Cel-
sius
. The temperature for each seal shoe should
be increased or decreased as needed after running a peel force test.
2.
Allow the heat sealer to reach its operating temperature before continuing.
Caution! Temperature Hazard!
Touching the heat block guard while the Heat Sealer is in operation may
result in burns. Use care when working near this area and allow it to cool
before performing maintenance.
3.
Adjust the heat shoe
Seal Pressure
to the
appropriate setting. This setting controls the
amount of force applied when the sealer
shoes drop. PSI can be set anywhere
between 40-60 psi.
Turning the
Seal Pressure
control clockwise
will increase the pressure, while turning it
counter-clockwise will decrease the
pressure.
Step 5:
Setup
Output
HEAT
SEALER
A
B
C
D
Содержание TM-500
Страница 2: ...European Representative QNET BV Hommerterweg 286 6436 AM Amstenrade The Netherlands...
Страница 17: ...Contact Information D292144 2 fm xiv...
Страница 21: ...Table of Contents D292144 3a fm...
Страница 47: ...2 14 TM 500 User s Guide Dual Tray Feeder Input Output Module D292144 5 fm...
Страница 83: ...3 36 TM 500 User s Guide The Setup Screens D292144 6 fm...
Страница 187: ...7 14 TM 500 User s Guide Ethernet Networks D292144 10 fm...
Страница 254: ...751 Summit Avenue Mankato MN 56001 507 387 2039 FAX 507 387 2257 www vtekusa com Email info vtekusa com...