D292144.9.fm
System Alarm Messages
Chapter 6: Troubleshooting
6-5
Part Not Picked System Alarm
If the nozzle is unable to pick a part from the
Dual Tray
Input Module
, the
Part Not Picked
system
alarm will be activated. When this happens, operation stops, a beep sounds, and a warning
appears on the HMI.
To clear the
Part Not Picked Alarm,
ensure there are parts in the tray feeder and it is feeding
properly. If that does not resolve the problem, ensure the
Pick Height
is not set too high and the
Nozzle Pick Dwell Time
is not set too low.
When the
Input Module
is ready for operation, press
CONTINUE
to clear the alarm and resume
operation.