207
REMOTE COMMAND
【
Remote Communication Format
】
BPS rate
: 4800/9600/19200/38400/57600/115200 bps
Start/Stop bit : 1 bit, 1 bit
Data Length
: 8 bit
Parity Check
: None
Code
: ASCII
Flow Control
: None
Return Code
: Carriage Return only
【
FORMAT OF THIS DOCUMENT
】
<COMMAND NAME>
Summary explanation of the function of the command
Controller
→
Radio
Command format
Radio
→
Controller
Response format
NOTE
1.
Commands are required to wait a response from the scanner, then, next command is accepted.
2.
All memory access commands are acceptable in only Program Mode.
Use PRG command to enter Program Mode, and EPG command to exit.
3.
Error messages aren’t described for each command, but the scanner returns error message to the controller as
follows.
1) Command format error / Value error : ERR[\r]
2) The command is invalid at the time : NG[\r]
3) Framing error
: FER[\r]
4) Overrun error
: ORER[\r]
4.
[\r] means "to hit the Enter key" or "to send the Return code".
5.
Several commands or responses with long format are described like multi-line because of the page width but
their formats are only single line, actually.
In set command, only "," parameters are not changed.
6.
The set command is aborted if any format error is detected.
7.
[INDEX] or [xxx_INDEX] is the index of internal memory chain.
Dynamic Memory Allocation Structure always uses it as a handle to access data and to trace
forward/reverse or up/down index.
The range of the index is from 1 to maximum memory block (about 45000).
8.
[FRQ], [BASEx] and [LIMIT_x] are frequency format.
It is showed by 8 digit number without decimal point.
The order of the digits is from 1 GHz digit to 100 Hz digit.
ex. 08510125 means 851.0125MHz
9.
[TGID] shows TGID format. The formats depend on Trunked System Type.
See another Appendix to get further information.
10.
[NAME] shows each custom name. If you set only a space character, the name will return to default
name.
11.
[LATITUDE] shows North or South Latitude.
The data shows “DDMMSSssL” at DMS Format.
DD
:
Degree
( 00 - 90 : Double figure fixation )
MM
:
Minute
( 00 - 59 : Double figure fixation )
SSss
:
Second
( SS : 00 - 59 : Double figure fixation )
Содержание BC346XT
Страница 515: ...266 ...
Страница 516: ...267 ...
Страница 517: ...268 ...
Страница 518: ...269 ...
Страница 519: ...270 ...
Страница 520: ...271 Character pattern of 8 x 8 dot This character pattern is Small Font ...
Страница 521: ...272 ...
Страница 522: ...273 ...
Страница 814: ...256 ...
Страница 815: ...257 ...
Страница 816: ...258 ...
Страница 817: ...259 ...
Страница 818: ...260 ...
Страница 819: ...261 Character pattern of 8 x 8 dot This character pattern is Small Font ...
Страница 820: ...262 ...
Страница 821: ...263 ...
Страница 831: ......