background image

 

August 1998

45893

 

IQ plus

 

®

 

 510/710 Digital Weight Indicators

 

Relay Rack Option

 

PN 45408

 

Use the following procedure to install the IQ plus
510/710 relay rack option:

1. Ensure power to the indicator is disconnected,

then place the indicator face-down on an
antistatic work mat. Remove the screws that
hold the backplate to the enclosure body.
Loosen all in-use cord grips then lift the
backplate away from the enclosure and set it
aside. 

 

Use a wrist strap to ground yourself and
protect components from electrostatic
discharge (ESD) when working inside
the indicator enclosure.

 

2. A s s e m b l e   r e l a y s   o n t o   t h e   r e l a y   b o a r d

(4-channel) or boards (8-channel).

3. Install standoffs onto the studs on the

indicator backplate. Mount U-brackets on the
standoffs, place protective shield on top of
brackets, and secure with kep nuts (see
Figure 3 on page 2).

4. For IQ plus 710 indicators using output

relays, remove connector J8 from the CPU
b o a r d   a n d   w i r e   t h e   r e l a y   b o a r d   t o   t h e
connector as shown in Figure 1. 

For IQ plus 510 or 710 input relays, remove
connectors J7 and J8 from the CPU board and
wire as shown in Figure 2.

 

NOTE:

 

 For indicators using Rev. 1 CPU boards,

digital input and output connections are made to
the interface board. See the 

 

IQ plus 510/710

Interface Board

 

 addendum, PN 46204, for

connector information.

 

5. Loosen cord grips and route cables for

external equipment into the enclosure as
shown in Figure 3 on page 2. Attach cables to
relay board as shown in Figure 1 or Figure 2.

 

(Continued on back…)

Figure 1. IQ plus 710 Output Relay Wiring

Figure 2. IQ plus 510/710 Input Relay Wiring

Caution

RELAY_B1

RELAY_D1

Input A

Input B

Gnd

+5VDC

Logic

RELAY_A1

RELAY_C1

J2

R2 R1

R3

R4

Input A

Input B

+5VDC

Logic

Gnd

Input A

Input B

+5VDC

Logic

Gnd

Input A

Input B

+5VDC

Logic

Gnd

+5V

GND

AB

C

D

A

B

C

D

J1

J8-10 (+5V)

J8-2 (DIGOUT 1)

J8-3 (DIGOUT 2)

J8-4 (DIGOUT 3)

J8-5 (DIGOUT 4)

J8-1 (GND)

From Digital Outputs

(J8 connector on

IQ plus 710 CPU board)

Relay output

to equipment

A.C.

A.C.

AC HOT IN

OUTPUT RELAYS

RELAY_B1

RELAY_D1

Input A

Input B

Gnd

+5VDC

Logic

RELAY_A1

RELAY_C1

J2

R2 R1

R3

R4

Input A

Input B

+5VDC

Logic

Gnd

Input A

Input B

+5VDC

Logic

Gnd

Input A

Input B

+5VDC

Logic

Gnd

+5V

GND

AB

C

D

A

B

C

D

J1

J8-10 (+5V)

J7-2 (DIGIN 1)

J7-3 (DIGIN 2)

J7-4 (DIGIN 3)

J7-5 (DIGIN 4)

J7-1 (GND)

To Digital Inputs

(J7 connector on

IQ plus 510/710 CPU board)

Relay input

from equipment

A.C.

A.C.

AC NEUTRAL IN

INPUT RELAYS

 

Отзывы: