E6581611
F-122
6
6.33.3 Calibration of analog output
f681
: Analog output signal selection
f684
: Analog output filter
f691
: Inclination characteristic of analog output
f692
: Analog output bias
•
Function
Output signal from the FM terminal can be switched between 0 to 1mAdc output, 0 to 20mAdc output,
and 0 to 10Vdc output with the
f681
setting. The standard setting is 0 to 1mAdc output.
* Optional frequency meter: When using QS60T, set
f681
=
0
(meter option (0 to 1mA) output).
[Parameter setting]
Title
Function
Adjustment range
Default setting
f681
Analog output signal selection
0: Meter option (0 to 1mA)
1: Current (0 to 20mA) output
2: Voltage (0 to 10V) output
0
f684
Analog output filter
2-1000 (ms)
2
f691
Inclination characteristic of analog
output
0: Negative inclination (downward slope)
1: Positive inclination (upward slope)
1
f692
Analog output bias
-1.0 - +100.0 (%)
0.0
Note 1: In case of 0 to 20mAdc (4 to 20mAdc) output, or 0 to 10Vdc output, set
f681
to
1
or
2
.
In case of 4 to 20mAdc output,
f692
needs adjustment.