E6581611
G-2
7
7.2
Applied operations by an I/O signal (operation from
the terminal block)
Input terminal sink and source logic are set by using slide switch SW1.
7.2.1 Input
terminal
function
(sink logic)
This function is used to send a signal to the
input terminal from an external programmable
controller to operate or configure the inverter.
The ability to select from a variety of functions
allows for flexible system design.
Default settings of slide switch SW1and SW2 are
as follows;
SW1: PLC side, SW2: VIB side and S3 side.
Refer to page B-11 to 13 for details.
Settings for the logic input terminal function
Terminal
symbol
Title
Function
Adjustment range
Default setting
Input terminal selection 1A (F)
2 (F)
Input terminal selection 1B (F)
0 (No function)
F
Input terminal selection 1C (F)
0-203 Note 1)
0 (No function)
Input terminal selection 2A (R)
4 (R)
Input terminal selection 2B (R)
0 (No function)
R
Input terminal selection 2C (R)
0-203 Note 1)
0 (No function)
Input terminal selection 3A (RES)
8 (RES)
RES
Input terminal selection 3B (RES)
0-203 Note 1)
0 (No function)
Input terminal selection 4A (S1)
10 (SS1)
S1
Input terminal selection 4B (S1)
0-203 Note 1)
0 (No function)
Input terminal selection 5 (S2)
0-203 Note 3)
12 (SS2)
S2
f146
Logic input / pulse train input
selection (S2)
0: Logic input
1: Pulse train input
0
Input terminal selection 6 (S3)
0-203 Note 4)
14 (SS3)
S3
f147
Logic input / PTC input selection (S3)
0: Logic input
1: PTC input
0
VIB
Input terminal selection 7 (VIB)
8-55 Note 5)
16 (SS4)
VIA
Input terminal selection 8 (VIA)
8-55 Note 6)
24 (AD2)
VIA
VIB
Analog/logic input selection (VIA/VIB) 0-4
0
F to VIB
Input terminal response time
1-1000 (ms) Note 7)
1
[Control terminal block]
VIC
FM
S3
FLA
RY
FLC
FLB
VIA
CC
VIB
PP
RC
F
CC
R
NO
P24
OUT
+24
CC +SU
S2
RES S1
SINK
SOURCE
SW1
PLC
VIB
SW2
PTC
S3
S4
Содержание Q9 Plus ASD
Страница 5: ...TM Q9 Plus Bypass ASD Bypass Box INSTALLATION OPERATION MANUAL June 2013 DN 68251 000 ...
Страница 61: ...Q9 PLUS ASD LOW VOLTAGE DRIVE ...
Страница 65: ...S15 ASD LOW VOLTAGE DRIVE ...
Страница 80: ...E6581611 iv 15 Warranty O 1 16 Disposal of the inverter P 1 ...
Страница 429: ......
Страница 430: ......