E6581611
K-37
11
Table of output terminal functions 4
Function
No.
Code Function
Action
Reference
144
PIDF
Signal in accordance of frequency command
ON: Frequency commanded by
and
are
within
±
.
OFF: Other than those above
6.24
145
PIDFN
Inversion of signal in accordance of
frequency command
Inversion of PIDF
146
FLR
Fault signal (output also at a retry waiting)
ON: While inverter is tripped or retried
OFF: While inverter is not tripped and not retried
6.19.3
147
FLRN
Inversion of fault signal (output also at a
retry waiting)
Inversion of FLR
150
PTCA
PTC input alarm signal
ON: PTC thermal input value is
f646
or more
OFF: PTC thermal input value is less than
f646
6.29.16
151
PTCAN
Inversion of PTC input alarm signal
Inversion of PTCA
152, 153
Factory specific coefficient
-
*1
154
DISK
Analog input break detection alarm
ON: VIB terminal input value is
f633
or less
OFF: VIB terminal input value is more than
f633
6.29.14
155
DISKN
Inversion of analog input break detection
alarm
Inversion of DISK
156
LI1
F terminal status
ON: F terminal is ON status
OFF: F terminal is OFF status
7.2.2
157
LI1N
Inversion of F terminal status
Inversion of LI1
158
LI2
R terminal status
ON: R terminal is ON status
OFF: R terminal is OFF status
159
LI2N
Inversion of R terminal status
Inversion of LI2
160
LTAF
Cooling fan replacement alarm
ON: Cooling fan reaches parts replacement time
OFF: Cooling fan does not reach parts replacement time
6.29.15
161
LTAFN
Inversion of cooling fan replacement alarm
Inversion of LTAF
162
NSA
Number of starting alarm
ON: Number of starting alarm is
f648
or more
OFF: Number of starting alarm is less than
f648
6.29.17
163
NSAN
Inversion of number of starting alarm
Inversion of NSA
166
DACC
Acceleration operation in progress
ON: Acceleration operation in progress
OFF: Other than those above
7.2.2
167 DACCN Inversion
of
acceleration operation in
progress
Inversion of DACC
168
DDEC
Deceleration operation in progress
ON: Deceleration operation in progress
OFF: Other than those above
169 DDECN Inversion
of
deceleration operation in
progress
Inversion of DDEC
170
DRUN
Constant speed operation in progress
ON: Constant speed operation in progress
OFF: Other than those above
171 DRUNN Inversion
of
constant speed operation in
progress
Inversion of DRUN
172
DDC
DC braking in progress
ON: DC braking in progress
OFF: Other than those above
6.12.1
173 DDCN Inversion
of
DC braking in progress
Inversion of DDC
174 to 179
Factory specific coefficient
-
*1
180
IPU
Integral input power pulse output signal
ON: Integral input power unit reach
OFF: Other than those above
6.33.1
182
SMPA
Shock monitoring pre-alarm signal
ON: Current / torque value reach the shock monitoring
detection condition
OFF: Other than those above
6.28
183 SMPAN Inversion of
s
hock monitoring pre-alarm
signal
Inversion of SMPA
222 to 253
Factory specific coefficient
-
*1
254
AOFF
Always OFF
Always OFF
7.2.2
255
AON
Always ON
Always ON
*1: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Note 1: As function No. that are not described in the table above are assigned "No function", output signal is always “OFF” at
even number, output signal is always “ON” at odd number.
Содержание Q9 Plus ASD
Страница 5: ...TM Q9 Plus Bypass ASD Bypass Box INSTALLATION OPERATION MANUAL June 2013 DN 68251 000 ...
Страница 61: ...Q9 PLUS ASD LOW VOLTAGE DRIVE ...
Страница 65: ...S15 ASD LOW VOLTAGE DRIVE ...
Страница 80: ...E6581611 iv 15 Warranty O 1 16 Disposal of the inverter P 1 ...
Страница 429: ......
Страница 430: ......