Q9 Plus Bypass ASD/Bypass Box Installation and Operation Manual
Installation Precautions
Location and Ambient Requirements
•
The TIC
Q9 Plus Bypass ASD/Q9 Plus Bypass Box
is intended for permanent installations only.
•
Installation shall conform to the
National Electrical Code
(NEC) —
Article 110
(Requirements
for Electrical Installations), all regulations of the
Occupational Safety and Health
Administration
, and any other applicable national, regional, or industry codes and standards.
•
Select a mounting location that is easily accessible, has adequate personnel working space, and
adequate illumination for adjustment, inspection, and maintenance of the equipment (refer to NEC
Article 110-13).
•
DO NOT
mount the
Q9 Plus Bypass ASD/Q9 Plus Bypass Box
in a location that would produce
catastrophic results if it were to become dislodged from its mounting location (equipment damage
or injury).
•
DO NOT
mount the
Q9 Plus Bypass ASD/Q9 Plus Bypass Box
in a location that would allow it
to be exposed to flammable chemicals or gases, water, solvents, explosive/corrosive mists or gases,
or other fluids.
•
The ambient operating temperature range of the
Q9 Plus Bypass ASD/Q9 Plus Bypass Box
is 14°
to 104° F (-10° to 40° C).
•
The installation location shall not be exposed to direct sunlight.
•
Avoid installation in areas where vibration, heat, humidity, dust, fibers, metal particles, explosive/
corrosive mists or gases, or sources of electrical noise are present.
•
Allow proper clearance spaces for installation.
DO NOT
obstruct the ventilation openings. Refer to
the section titled
Installation and Connections
of the
Q9 Plus ASD Installation & Operation
Manual
(D/N 68249) for further information on installation and ventilation requirements.
Mounting Requirements
•
Only
are to install this equipment.
•
Install the unit in a secure and upright position in a well-ventilated area.
•
As a minimum, the installation of the equipment shall conform to the
NEC — Article 110
(NEC),
OSHA, as well as any other applicable national, regional, or industry codes and standards.
•
Installation practices shall conform to the latest revision of NFPA 70E Electrical Safety
Requirements for Employee Workplaces.
•
It is the responsibility of the person installing the
Q9 Plus Bypass ASD/Q9 Plus Bypass Box
or
the electrical maintenance personnel to ensure that the unit is installed into an enclosure that will
protect personnel against electric shock.
Содержание Q9 Plus ASD
Страница 5: ...TM Q9 Plus Bypass ASD Bypass Box INSTALLATION OPERATION MANUAL June 2013 DN 68251 000 ...
Страница 61: ...Q9 PLUS ASD LOW VOLTAGE DRIVE ...
Страница 65: ...S15 ASD LOW VOLTAGE DRIVE ...
Страница 80: ...E6581611 iv 15 Warranty O 1 16 Disposal of the inverter P 1 ...
Страница 429: ......
Страница 430: ......