Steps in setting are as follows
(In this example, the V/F control mode selection parameter
is set to
(Vector control).
[Setting V/F control mode selection to 3 (sensorless vector control)]
Operation panel
action
LED display
Operation
.
Displays the output frequency. (Perform during operation stopped.)
(When standard monitor display selection
is set to
[output frequency])
The first basic parameter “
” (history function) is displayed.
Rotate the setting dial to the right, and change the parameter to
(V/F control mode selection).
Set values are displayed by pressing the center of the setting dial.
Rotate the setting dial to the right, and change the parameter to
(vector control).
Press the center of the setting dial to save the changed set value.
and the set value “
” are displayed alternately.
Caution:
When the V/F control mode selection
is set to
: Automatic torque boost control,
: Vector control,
: Energy-saving,
: Dynamic energy-saving, or
: PM motor control, be sure to set the following
parameters according to the motor's name plate.
: Base frequency 1 (rated frequency)
: Base frequency voltage 1 (rated voltage)
: Motor rated capacity
: Motor rated current
: Motor rated speed
Set the other motor constants as necessary
MODE
Содержание Q9 Plus ASD
Страница 5: ...TM Q9 Plus Bypass ASD Bypass Box INSTALLATION OPERATION MANUAL June 2013 DN 68251 000 ...
Страница 61: ...Q9 PLUS ASD LOW VOLTAGE DRIVE ...
Страница 65: ...S15 ASD LOW VOLTAGE DRIVE ...
Страница 80: ...E6581611 iv 15 Warranty O 1 16 Disposal of the inverter P 1 ...
Страница 429: ......
Страница 430: ......