6.10.4 Setting of frequency with the input from an external logic
: External logic input - UP response time
: External logic input - UP frequency steps
: External logic input - DOWN response time
: External logic input - DOWN frequency steps
: Initial value of UP/DOWN frequency
: Change of the initial value of UP/DOWN frequency
Function
These parameters are used to set an output frequency by means of a signal from an external device.
[Parameter setting]
Title
Function
Adjustment range
Default setting
f264
External logic input - UP response
time
0.0 - 10.0 (s)
0.1
f265
External logic input - UP frequency
steps
0.0 -
fh
(Hz)
0.1
f266
External logic input - DOWN response
time
0.0 - 10.0 (s)
0.1
f267
External logic input - DOWN frequency
steps
0.0 -
fh
(Hz)
0.1
f268
Initial value of UP/DOWN frequency
-
(Hz)
0.0
f269
Change of the initial value of
UP/DOWN frequency
0: Not changed
1: Setting of
changed
when power is turned off
1
,
This function is valid when the parameter
fmod
(Frequency setting mode selection 1) =
5
is set.
■
Input terminal settings
Assigning the following functions to the input terminal will allow you to change (up/down) or clear the output
frequency by using the terminal's ON/OFF.
Input terminal function
ON
OFF
88
Frequency UP
Frequency setting increase
Clear
90
Frequency DOWN
Frequency setting decrease
Clear
92
Clear frequency UP/DOWN
OFF
¤
ON: External logic up/down
frequency clear settings
f268
settings
Each of the following numbers (89, 91, 93) are reverse signals.
Содержание Q9 Plus ASD
Страница 5: ...TM Q9 Plus Bypass ASD Bypass Box INSTALLATION OPERATION MANUAL June 2013 DN 68251 000 ...
Страница 61: ...Q9 PLUS ASD LOW VOLTAGE DRIVE ...
Страница 65: ...S15 ASD LOW VOLTAGE DRIVE ...
Страница 80: ...E6581611 iv 15 Warranty O 1 16 Disposal of the inverter P 1 ...
Страница 429: ......
Страница 430: ......