e-STUDIO170F Removal/Replacement/Adjustment
January 2005 © TOSHIBA TEC
8 - 32
[ 4 ] Fuser
• Before disassembling or reassembling, be sure to refer to
P.8-1 "8.1 Before Disassembling or
Reassembling".
• Be careful not to touch the sharp edge on the left side frame indicated in notes of chapter 8.1.
(1) Remove the rear cover assembly. (Refer to
P.8-8 "[ 5 ] Rear Cover Assembly")
(2) Push the release button and open the RX cover assembly.
(3) Remove the one screw. Slide the RX cover stopper and pull out the hook of the RX cover stopper
from the hole.
Fig.8-44
(4) Remove the three screws from the RX unit. Remove the RX unit by sliding it upward.
Fig.8-45
RX cover stopper
Screw
RX unit