8
January 2005 © TOSHIBA TEC
e-STUDIO170F Removal/Replacement/Adjustment
8 - 11
(5) Remove the ground cable from the W1 or W2 on the NCU PBA.
(6) Release the three hooks of the PBA plate, and remove the NCU PBA.
Notes:
• Carefully handle the boards that are directly connected together to avoid damaging the con-
nectors and boards.
• For IT, DK, and FI machines of EU model, connect the ground cable to the W1. Connect the
ground cable to the W2 with the machines of EU and AU models for all other destinations.
• US/CA, SG and HK model equip the terminal W1 only (no W2 is equipped).
Fig.8-12
PBA plate
Hook
Hook
W1 or W2
NCU PBA