e-STUDIO170F Troubleshooting
January 2005 © TOSHIBA TEC
11 - 46
[ 4 ] Communication error codes
By referring to the communication error code printed on the communication journal, you can confirm the
contents of the error that occurred during each communication.
Error Code
Cause
Remedy
10
There was no recording paper or the recording
paper tray was not installed during the reception.
Supply recording paper and insert the
recording paper tray firmly.
11
A recording paper jam occurred during the recep-
tion.
Open the RX cover or front cover and
remove the jammed recording paper.
12
A document jam occurred.
Open the operation panel, and remove the
jammed document, then try the transmis-
sion again.
13
During the transmission, the RX cover or front
cover was opened and the transmission stopped.
Attempt the transmission again.
20
A power failure occurred during the transmission
or reception, and the transmission/reception doc-
ument data was lost.
Attempt the transmission or reception
again.
22
A file error occurred due to a directory error.
Perform a full memory clear. If the error
recurs, replace the main PBA.
30
The [STOP] key was pressed during the commu-
nication, and the communication was stopped.
Attempt the transmission or reception
again.
32
The set number of document pages did not
match the actual pages transmitted.
Check the actual document count.
33
The polling password did not match, or no polling
document existed.
Check the polling password or check if
there is a polling document on the remote
party’s side, and attempt the polling recep-
tion again.
42
During a memory transmission or a memory
reception, the machine ran out of image memory.
The machine's image memory was exhausted.
Divide the documents into several trans
missions for a memory transmission.
For a memory reception, remove the cause
of the error, then ask the remote party to
transmit the document again.
50
Dialing and redialing was attempted as many as
the specified count but the line was busy.
Confirm the phone numbers of the remote
party.
53
The password did not match in a relay or mailbox
transmission, and the transmission ended in fail-
ure.
Confirm that both parties are using the
same system password and the both units
are compatible. Then, ask the remote party
to transmit again.
87
There was no residual memory in the remote
party’s fax unit during a relay/mailbox transmis-
sion.
Attempt the transmission again.
B0
DIS (GI) could not detected.
This may happen in some cases of bad
line condition. Attempt the transmission
again.
B1
DIS/NSF that cannot be handled by the sender is
received.
The receiver received NSS/DCS other than those
declared by DIS/NSF.
This may happen in some cases of bad
line condition. Attempt the transmission
again or ask the remote party to attempt
the transmission again.
B2
DCN is received.
This may happen in some cases of bad
line condition. Attempt the transmission
again.
B3
DCS/DTC was not detected.
This may happen in some cases of bad
line condition. Attempt the transmission
again.
B4
The sender performed fall-back but the transmis-
sion was not enabled.
The receiver performed time-out after sending
FTT. Or DCN is received.
This may happen in some cases of bad
line condition. Attempt the transmission
again. Or ask the remote party to attempt
the transmission again.
Содержание ESTUDIO170F
Страница 1: ...SERVICE MANUAL PLAIN PAPER FACSIMILE e STUDIO170F File No SME04002900 R04102171300 TTEC Ver01_2005 05 ...
Страница 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 192: ...e STUDIO170F Function Settings January 2005 TOSHIBA TEC 4 132 ...
Страница 214: ...e STUDIO170F Mechanical Description January 2005 TOSHIBA TEC 5 22 ...
Страница 308: ...e STUDIO170F Circuit Description January 2005 TOSHIBA TEC 7 78 ...
Страница 372: ...e STUDIO170F Removal Replacement Adjustment January 2005 TOSHIBA TEC 8 64 ...
Страница 490: ...e STUDIO170F Appendix January 2005 TOSHIBA TEC 12 8 ...
Страница 491: ......
Страница 492: ......