e-STUDIO170F Circuit Description
January 2005 © TOSHIBA TEC
7 - 52
• Sub-CPU (IC56) Signal Table
Pin No.
Signal name
I/O
Function
1
XOUT
O
Sub-CPU operation clock output (4 MHz)
2
XIN
I
Sub-CPU operation clock input (4 MHz)
3
2WRESETX
I
Sub-CPU power on reset signal (Low-active)
Resets the Sub-CPU (IC56) when the power is turned
on.
4
WTOX
O
Sub-CPU reset signal (Low-active)
Resets the Sub-CPU.
5
LEDBLK
I
Power save LED blinking signal (Low-active)
The ASIC (I/O port: IC38) requests the Sub-CPU to
blink the power save LED.
6
R72
I
+5VPS power up detect signal (High-active)
7
PWRSVKEY
I
Key input detect signal (Low-active)
Detects the press status of each key switch installed on
the Operation panel PBA.
8
DDET
I
Document detect signal (Low-active)
Detects the presence or absence of a document.
9
PWRSVACK
I
Power save acknowledge signal (Low-active)
The ASIC (I/O port) enables the Sub-CPU to move to
the Power Save mode.
10
PWRSVNACK
I
Power save non-acknowledge signal (Low-active)
The ASIC (I/O port) indicates return from the Power
Save mode to the Sub-CPU.
11
PWRSVLED
O
Power save LED lighting signal (L: Lit)
Controls the lighting of the power save LED installed on
the Operation panel PBA.
12
R51
-
Not used (Open)
13
PWRSVDI
O
Port enable signal (Low-active)
Controls the inputs of the signals input to the NCU PBA
and the document detect signal.
14
VSS
-
Signal ground
15
PSC
O
Power save control signal (Low-active)
Limits the power supply from the LVPS in Power Save
mode.
16
HOOK
I
Hook detect signal (H: On-hook, L: Off-hook)
Detects the hook status of the handset.
17
CISX
I
CI detect signal (H: Undetected, L: Detected)
Detects the ring signal sent from the line.
18
REV
I
Line current detect signal
Detects the current and the reverse current flowing
through the line.
19
VBUSDET
I
PC interrupt signal (Low-active)
Detects the interrupt signal from the PC.
20-23
R80-83
-
Pull-down: signal ground
24
R90
-
Not used (Open)
25
CIREQ
O
CI request signal (Low-active)
Indicates the detection of CI to the ASIC (I/O port).
26
PWRSVREQ
O
Power save request signal (Low-active)
Requests the ASIC (I/O port) to move to the Power
Save mode.
27
KE0X/HOLDX
-
Pull-up: +5VPS
28
VDD
-
+5VPS
Содержание ESTUDIO170F
Страница 1: ...SERVICE MANUAL PLAIN PAPER FACSIMILE e STUDIO170F File No SME04002900 R04102171300 TTEC Ver01_2005 05 ...
Страница 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 192: ...e STUDIO170F Function Settings January 2005 TOSHIBA TEC 4 132 ...
Страница 214: ...e STUDIO170F Mechanical Description January 2005 TOSHIBA TEC 5 22 ...
Страница 308: ...e STUDIO170F Circuit Description January 2005 TOSHIBA TEC 7 78 ...
Страница 372: ...e STUDIO170F Removal Replacement Adjustment January 2005 TOSHIBA TEC 8 64 ...
Страница 490: ...e STUDIO170F Appendix January 2005 TOSHIBA TEC 12 8 ...
Страница 491: ......