[ 6 ] EDGE REGISTRATION [MENU], [9], [5], [06]
This setting adjusts the recording start position (lead edge and side edge) if incorrect due to mechanical
dispersion. Do this adjustment when the Main PBA is replaced or when MEMORY CLEAR is per-
formed. Do it also when the LSU is replaced if necessary.
Remark:
For the adjustment value of edge registration, refer to
P.8-56 "8.3.1 Edge Registration".
1) Use the [
Ç
] or [
È
] key to select "06.EDGE REGISTRATION", and then press the [ENTER] key.
2) Use the [
Ç
] or [‚] key to set the LEAD EDGE (upper side), and then press the [ENTER] key.
Remarks:
• Pressing the [
Ç
] key will move the image up 0.5 mm per step.
Pressing the [
È
] key will move the image down 0.5 mm per step.
• The setting range is -7.5 mm to +7.5 mm.
3) Use the [
Ç
] or [
È
] key to set the SIDE EDGE (left side), and then press the [ENTER] key.
Remarks:
• Pressing the [
Ç
] key will move the image left 0.5 mm per step.
Pressing the [
È
] key will move the image right 0.5 mm per step.
• The setting range is -6.0 mm (Left) to +8.0 mm (Right.)
4) The display shows the screen below, and then returns to the standby mode screen.
Effective recording area
Lead edge
Side edge
Recording paper
Feed direction
LEAD EDGE
19 . +1.5MM
SIDE EDGE
15 . +1.0MM
COMPLETED
Содержание ESTUDIO170F
Страница 1: ...SERVICE MANUAL PLAIN PAPER FACSIMILE e STUDIO170F File No SME04002900 R04102171300 TTEC Ver01_2005 05 ...
Страница 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 192: ...e STUDIO170F Function Settings January 2005 TOSHIBA TEC 4 132 ...
Страница 214: ...e STUDIO170F Mechanical Description January 2005 TOSHIBA TEC 5 22 ...
Страница 308: ...e STUDIO170F Circuit Description January 2005 TOSHIBA TEC 7 78 ...
Страница 372: ...e STUDIO170F Removal Replacement Adjustment January 2005 TOSHIBA TEC 8 64 ...
Страница 490: ...e STUDIO170F Appendix January 2005 TOSHIBA TEC 12 8 ...
Страница 491: ......
Страница 492: ......