8
January 2005 © TOSHIBA TEC
e-STUDIO170F Removal/Replacement/Adjustment
8 - 19
[ 4 ] TX Feed Rollers
Before disassembling or reassembling, be sure to refer to
P.8-1 "8.1 Before Disassembling or Reas-
sembling".
(1) Remove the TX cover. (Refer to
P.8-17 "[ 2 ] TX Cover")
(2) Lift the TX feed roller assembly, and release the left side of the TX feed roller from the guide.
(3) Slide the TX feed roller assembly to the left, and release the shaft holder on the right of the TX
feed roller assembly from the TX frame. Then, remove the TX feed roller assembly.
Fig.8-23
(4) Remove the gear and the two shaft holders from the TX feed roller assembly.
Fig.8-24
TX feed roller assembly
Shaft holder
(Plastic)
Shaft holder
TX feed roller
Gear