8
January 2005 © TOSHIBA TEC
e-STUDIO170F Removal/Replacement/Adjustment
8 - 31
[ 3 ] LSU
• Before disassembling or reassembling, be sure to refer to
P.8-1 "8.1 Before Disassembling or
Reassembling".
• Be careful not to touch the sharp edge on the left side frame indicated in notes of chapter 8.1.
(1) Remove the TX drive assembly. (Refer to
P.8-15 "[ 1 ] TX Drive Assembly")
(2) Disconnect the one connector from the main PBA.
(3) Remove the three screws and disconnect the one cable from the LSU, and then remove the
LSU.
Note:
After reassembling, perform the print test referring to the
P.11-12 "[ 7 ] PRINT TEST [MENU],
[9], [2], [07]". If necessary, perform the edge registration adjustment referring to the
P.8-56
"8.3.1 Edge Registration".
Fig.8-43
LSU
Screw
Cable