e-STUDIO170F Troubleshooting
January 2005 © TOSHIBA TEC
11 - 22
[ 8 ] MF RX TEST [MENU], [9], [4], [08]
This test checks the action of the MF-tone receiving.
This test is performed at the factory for inspection and not required in the field.
1) Use the [
Ç
] or [
È
] key to select the "08.MF RX TEST", and then press the [ENTER] key.
2) When an MF tone is received from another facsimile, the corresponding character is displayed. The
character is updated and overwritten by a new tone received. To stop the test (at any time), press
the [STOP] key and return to the standby mode screen.
3) When you complete the test, press the [STOP] key to return to the standby mode screen.
[ 9 ] CLOCK TEST [MENU], [9], [4], [09]
This test checks whether the RTC (IC52) operates normally. After setting the fixed time and date in the
RTC, it reads the time to check the RTC operation.
1) Use the [
Ç
] or [
È
] key to select “09. CLOCK TEST”, and then press the [ENTER] key.
2) When you complete the test, press the [STOP] key to return to the standby mode screen.
3) Depending on the result of the test, replace the Main PBA by referring to
P.8-12 "[ 2 ] Main PBA".
MF RX TEST
Received MF tone character (When 8 received)
MF RX TEST
8
CLOCK IC TEST
When the test has been
completed normally
CLOCK IC TEST
OK
Содержание ESTUDIO170F
Страница 1: ...SERVICE MANUAL PLAIN PAPER FACSIMILE e STUDIO170F File No SME04002900 R04102171300 TTEC Ver01_2005 05 ...
Страница 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 192: ...e STUDIO170F Function Settings January 2005 TOSHIBA TEC 4 132 ...
Страница 214: ...e STUDIO170F Mechanical Description January 2005 TOSHIBA TEC 5 22 ...
Страница 308: ...e STUDIO170F Circuit Description January 2005 TOSHIBA TEC 7 78 ...
Страница 372: ...e STUDIO170F Removal Replacement Adjustment January 2005 TOSHIBA TEC 8 64 ...
Страница 490: ...e STUDIO170F Appendix January 2005 TOSHIBA TEC 12 8 ...
Страница 491: ......
Страница 492: ......