Fault Mux Registers Reference
263
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Fault Mux
Table 6-18. DPWM 1 Fault AB Detection Register (DPWM1FLTABDET) Register Field
Descriptions (continued)
Bit
Field
Type
Reset
Description
2
ACOMP_C_EN
R/W
0
Enables Analog Comparator C result for DPWM 2 Current Limit
0 = Analog Comparator result disabled for current limit (Default)
1 = Analog Comparator result enabled for current limit
1
ACOMP_B_EN
R/W
0
Enables Analog Comparator B result for DPWM 2 Current Limit
0 = Analog Comparator result disabled for current limit (Default)
1 = Analog Comparator result enabled for current limit
0
ACOMP_A_EN
R/W
0
Enables Analog Comparator A result for DPWM 2 Current Limit
0 = Analog Comparator result disabled for current limit (Default)
1 = Analog Comparator result enabled for current limit