5.14.27 Peak Current Mode Control Register (PCMCTRL)
Address 00020068
Figure 5-28. Peak Current Mode Control Register (PCMCTRL)
5
4
3
0
PCM_FILTER_SEL
Reserved
R/W-00
R-0000
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 5-28. Peak Current Mode Control Register (PCMCTRL) Register Field Descriptions
Bit
Field
Type
Reset
Description
5-4
PCM_FILTER
_SEL
R/W
00
Selects source of Peak Current Slope Compensation Ramp Start
0 = Filter 0 data selected (Default)
1 = Filter 1 data selected
2 = Filter 2 data selected
3 = Constant Power/Constant Current data selected
3-0
Reserved
R
0000