Fault Mux Registers Reference
235
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Fault Mux
Figure 6-5. Analog Comparator Control 0 Register (ACOMPCTRL0)
30
24
ACOMP_B_THRESH
R/W-000 0000
23
22
21
19
18
17
16
Reserved
ACOMP_B_SEL
ACOMP_B
_POL
ACOMP_B_INT
_EN
Reserved
R-00
R/W-000
R/W-1
R/W-0
R-00
15
14
8
Reserved
ACOMP_A_THRESH
R-00
R/W-000 0000
7
6
5
3
2
1
0
Reserved
ACOMP_A_SEL
ACOMP_A
_SEL
ACOMP_A_INT
_EN
ACOMP_EN
R-00
R/W-000
R/W-1
R/W-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 6-1. Analog Comparator Control 0 Register (ACOMPCTRL0) Register Field Descriptions
Bit
Field
Type
Reset
Description
30-24
ACOMP_B_
THRESH
R/W
000 0000 Configures Analog Comparator B Threshold value
0 = Comparator Reference of 19.53125 mV (Default)
1 = Comparator Reference of 39.0625 mV
……..
127 = Comparator Reference of 2.5 V
23-22
Reserved
R
00
21-19
ACOMP_B_SEL
R/W
000
Configures Analog Comparator B Threshold
0 = Analog Comparator B Threshold set by ACOMP_B_THRESH (Default)
1 = Analog Comparator B Threshold set by Comparator Ramp 0
2 = Analog Comparator B Threshold set by Filter 0 Output
3 = Analog Comparator B Threshold set by Filter 1 Output
4 = Analog Comparator B Threshold set by Filter 2 Output
18
ACOMP_B_POL
R/W
1
Analog Comparator B Polarity
0 = Comparator result enabled when input falls below threshold
1 = Comparator result enabled when input exceeds threshold (Default)
17
ACOMP_B_INT_
EN
R/W
0
Analog Comparator B Interrupt Enable
0 = Disables Analog Comparator B Interrupt generation (Default)
1 = Enables Analog Comparator B Interrupt generation
16-15
Reserved
R
00
14-8
ACOMP_A_
THRESH
R/W
000 0000 Configures Analog Comparator A Threshold
0 = Comparator Reference of 19.53125 mV (Default)
1 = Comparator Reference of 39.0625 mV
……..
127 = Comparator Reference of 2.5 V
7-6
Reserved
R
00
5-3
ACOMP_A_SEL
R/W
000
Configures Analog Comparator A Threshold
0 = Analog Comparator A Threshold set by ACOMP_A_THRESH (Default)
1 = Analog Comparator A Threshold set by Comparator Ramp 0
2 = Analog Comparator A Threshold set by Filter 0 Output
3 = Analog Comparator A Threshold set by Filter 1 Output
4 = Analog Comparator A Threshold set by Filter 2 Output
2
ACOMP_A_POL
R/W
1
Analog Comparator A Polarity
0 = Comparator result enabled when input falls below threshold