Loop Mux Registers Reference
193
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Loop Mux
5.14.2 Front End Control 1 Mux Register (FECTRL1MUX)
Address 00020004
Figure 5-3. Front End Control 1 Mux Register (FECTRL1MUX)
13
12
11
10
9
8
NL_SEL
DPWM3_FRAME_
SYNC_EN
DPWM2_FRAME_
SYNC_EN
DPWM1_FRAME_
SYNC_EN
DPWM0_FRAME_
SYNC_EN
R/W-00
R/W-0
R/W-0
R/W-0
R/W-0
7
6
5
4
3
2
1
0
DPWM3_B_
TRIG_EN
DPWM2_B_
TRIG_EN
DPWM1_B_
TRIG_EN
DPWM0_B_
TRIG_EN
DPWM3_A_
TRIG_EN
DPWM2_A_
TRIG_EN
DPWM1_A_
TRIG_EN
DPWM0_A_
TRIG_EN
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 5-3. Front End Control 1 Mux Register (FECTRL1MUX) Register Field Descriptions
Bit
Field
Type
Reset
Description
13-12
NL_SEL
R/W
00
Configures source of Non-Linear (NL) comparison results used in Automatic Gain
Shifting
0 = Filter 0 NL Results used
1 = Filter 1 NL Results used
2 = Filter 2 NL Results used (Default)
11
DPWM3_FRAME_
SYNC_EN
R/W
0
Enables DPWM Trigger from DPWM 3 Frame Sync to Front End Control
0 = DPWM 3 Frame Sync not routed to Front End Control (Default)
1 = DPWM 3 Frame Sync routed to Front End Control
10
DPWM2_FRAME_
SYNC_EN
R/W
0
Enables DPWM Trigger from DPWM 2 Frame Sync to Front End Control
0 = DPWM 2 Frame Sync not routed to Front End Control (Default)
1 = DPWM 2 Frame Sync routed to Front End Control
9
DPWM1_FRAME_
SYNC_EN
R/W
0
Enables DPWM Trigger from DPWM 1 Frame Sync to Front End Control
0 = DPWM 1 Frame Sync not routed to Front End Control (Default)
1 = DPWM 1 Frame Sync routed to Front End Control
8
DPWM0_FRAME_
SYNC_EN
R/W
0
Enables DPWM Trigger from DPWM 0 Frame Sync to Front End Control
0 = DPWM 0 Frame Sync not routed to Front End Control (Default)
1 = DPWM 0 Frame Sync routed to Front End Control
7
DPWM3_B_TRIG_
EN
R/W
0
Enables DPWM Trigger from DPWM 3 PWM-B to Front End Control
0 = DPWM 3 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 3 PWM-B trigger routed to Front End Control
6
DPWM2_B_TRIG_
EN
R/W
0
Enables DPWM Trigger from DPWM 2 PWM-B to Front End Control
0 = DPWM 2 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 2 PWM-B trigger routed to Front End Control
5
DPWM1_B_TRIG_
EN
R/W
0
Enables DPWM Trigger from DPWM 1 PWM-B to Front End Control
0 = DPWM 1 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 1 PWM-B trigger routed to Front End Control
4
DPWM0_B_TRIG_
EN
R/W
0
Enables DPWM Trigger from DPWM 0 PWM-B to Front End Control
0 = DPWM 0 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 0 PWM-B trigger routed to Front End Control
3
DPWM3_A_TRIG_
EN
R/W
0
Enables DPWM Trigger from DPWM 3 PWM-A to Front End Control
0 = DPWM 3 PWM-A trigger not routed to Front End Control (Default)
1 = DPWM 3 PWM-A trigger routed to Front End Control
2
DPWM2_A_TRIG_
EN
R/W
0
Enables DPWM Trigger from DPWM 2 PWM-B to Front End Control
0 = DPWM 2 PWM-A trigger not routed to Front End Control (Default)
1 = DPWM 2 PWM-A trigger routed to Front End Control