Loop Mux Registers Reference
209
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Loop Mux
5.14.13 Constant Power Configuration Register (CPCONFIG)
Address 00020030
Figure 5-14. Constant Power Configuration Register (CPCONFIG)
25
16
15
10
9
0
MAX_CURRENT
Reserved
NOM_VOLTAGE
R/W-00 0000 0000
R-00 0000
R/W-00 0000 0000
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 5-14. Constant Power Configuration Register (CPCONFIG) Register Field Descriptions
Bit
Field
Type
Reset
Description
25-16
MAX_CURRENT
R/W
00 0000
0000
Configures I
MAX
setpoint used in Constant Power/Constant Current Calculations in
Max Current mode
15-10
Reserved
R
00 0000
9-0
NOM_VOLTAGE
R/W
00 0000
0000
Configures V
NOM
setpoint used in Constant Power/Constant Current Calculations in
Constant Voltage mode (Loop Oring configuration selected)