Loop Mux Registers Reference
204
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Loop Mux
Table 5-10. DPWM Mux Register (DPWMMUX) Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
13-12
DPWM0_SYNC
_SEL
R/W
00
Selects Master Sync for DPWM 0 when DPWM 0 configured in slave mode
0 = DPWM 0 Sync (Default)
1 = DPWM 1 Sync
2 = DPWM 2 Sync
3 = DPWM 3 Sync
11-9
DPWM3_FILTER
_SEL
R/W
010
Selects source of duty cycle/resonant period for DPWM Module 3
0 = Filter 0 Output Selected (Default)
1 = Filter 1 Output Selected
2 = Filter 2 Output Selected
3 = Constant Power Module Selected
4 = DPWM_ON_TIME value from Light Load Control Register
8-6
DPWM2_FILTER
_SEL
R/W
010
Selects source of duty cycle/resonant period for DPWM Module 2
0 = Filter 0 Output Selected (Default)
1 = Filter 1 Output Selected
2 = Filter 2 Output Selected
3 = Constant Power Module Selected
4 = DPWM_ON_TIME value from Light Load Control Register
5-3
DPWM1_FILTER
_SEL
R/W
001
Selects source of duty cycle/resonant period for DPWM Module 1
0 = Filter 0 Output Selected (Default)
1 = Filter 1 Output Selected
2 = Filter 2 Output Selected
3 = Constant Power Module Selected
4 = DPWM_ON_TIME value from Light Load Control Register
2-0
DPWM0_FILTER
_SEL
R/W
000
Selects source of duty cycle/resonant period for DPWM Module 0
0 = Filter 0 Output Selected (Default)
1 = Filter 1 Output Selected
2 = Filter 2 Output Selected
3 = Constant Power Module Selected
4 = DPWM_ON_TIME value from Light Load Control Register