Filter Registers Reference
177
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Filter
4.11.18 Filter Nonlinear Limit Register 2 (FILTERNL2)
Address 00060044 – Filter 2 Nonlinear Limit Register 2
Address 00090044 – Filter 1 Nonlinear Limit Register 2
Address 000C0044 – Filter 0 Nonlinear Limit Register 2
Figure 4-23. Filter Nonlinear Limit Register 2 (FILTERNL2)
24
16
15
9
8
0
LIMIT5
Reserved
LIMIT4
R/W-0 0000 0000
R-0
R/W-0 0000 0000
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 4-18. Filter Nonlinear Limit Register 2 (FILTERNL2) Register Field Descriptions
Bit
Field
Type
Reset
Description
24-16
LIMIT5
R/W
0 0000
0000
Configures LIMIT5 in Nonlinear Coefficient tables
15-9
Reserved
R
0
8-0
LIMIT4
R/W
0 0000
0000
Configures LIMIT4 in Nonlinear Coefficient tables