DPWM 0-3 Registers Reference
89
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Digital Pulse Width Modulator (DPWM)
Table 2-22. DPWM Interrupt Register (DPWMINT) Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
9
MODE_SWITCH
_INT_EN
R/W
0
Mode Switching Interrupt Enable
0 = Interrupt is not enabled (Default)
1 = Interrupt is enabled
8
FLT_A_INT_EN
R/W
0
Fault A Flag Interrupt Enable
0 = Interrupt is not enabled (Default)
1 = Interrupt is enabled
7
FLT_B_INT_EN
R/W
0
Fault B Flag Interrupt Enable
0 = Interrupt is not enabled (Default)
1 = Interrupt is enabled
6
FLT_AB_INT_EN
R/W
0
Fault AB Flag Interrupt Enable
0 = Interrupt is not enabled (Default)
1 = Interrupt is enabled
5
FLT_CBC_INT_EN R/W
0
Fault Cycle-by-Cycle Flag Interrupt Enable
0 = Interrupt is not enabled (Default)
1 = Interrupt is enabled
4
PRD_INT_EN
R/W
0
PWM Period Interrupt Enable
0 = Disables generation of periodic PWM interrupt (Default)
1 = Enables generation of periodic PWM interrupt
3-0
PRD_INT_SCALE
R/W
1111
This value scales the period interrupt signal from an interrupt every switching cycle to
16 switching cycles
0000 = Period Interrupt generated every switching cycle (Default)
0001 = Period Interrupt generated once every 2 switching cycles
0010 = Period Interrupt generated once every 4 switching cycles
0011 = Period Interrupt generated once every 6 switching cycles
0100 = Period Interrupt generated once every 8 switching cycles
0101 = Period Interrupt generated once every 16 switching cycles
0110 = Period Interrupt generated once every 32 switching cycles
0111 = Period Interrupt generated once every 48 switching cycles
1000 = Period Interrupt generated once every 64 switching cycles
1001 = Period Interrupt generated once every 80 switching cycles
1010 = Period Interrupt generated once every 96 switching cycles
1011 = Period Interrupt generated once every 128 switching cycles
1100 = Period Interrupt generated once every 160 switching cycles
1101 = Period Interrupt generated once every 192 switching cycles
1110 = Period Interrupt generated once every 224 switching cycles
1111 = Period Interrupt generated once every 256 switching cycles