Loop Mux Registers Reference
213
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Loop Mux
5.14.17 Constant Power Status Register (CPSTAT)
Address 00020040
Figure 5-18. onstant Power Status Register (CPSTAT)
8
7
6
5
4
3
2
1
0
CONSTANT
_CUR
CONSTANT
_PWR
CONSTANT
_VOLT
CC_TO_CV
_INT
CC_TO_CC
_INT
CV_TO_CC
_INT
CC_TO_CP
_INT
CP_TO_CV
_INT
CV_TO_CP
_INT
R-0
R-0
R-0
R-0
R-0
R-0
R-0
R-0
R-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 5-18. onstant Power Status Register (CPSTAT) Register Field Descriptions
Bit
Field
Type
Reset
Description
8
CONSTANT_CUR
R
0
Constant Current Mode Indication
0 = Constant Current Mode not enabled
1 = Constant Current Mode enabled
7
CONSTANT_PWR
R
0
Constant Power Mode Indication
0 = Constant Power Mode not enabled
1 = Constant Power Mode enabled
6
CONSTANT
_VOLT
R
0
Constant Voltage Mode Indication
0 = Constant Voltage Mode not enabled
1 = Constant Voltage Mode enabled
5
CC_TO_CV_INT
R
0
Constant Current Mode to Constant Voltage Mode latched status, cleared on read
0 = No transition from Constant Current to Constant Voltage detected
1 = Transition from Constant Current to Constant Voltage detected
4
CC_TO_CC_INT
R
0
Constant Voltage Mode to Constant Current Mode latched status, cleared on read
0 = No transition from Constant Voltage to Constant Current detected
1 = Transition from Constant Voltage to Constant Current detected
3
CV_TO_CC_INT
R
0
Constant Current Mode to Constant Power Mode latched status, cleared on read
0 = No transition from Constant Current to Constant Power detected
1 = Transition from Constant Current to Constant Power detected
2
CC_TO_CP_INT
R
0
Constant Power Mode to Constant Current Mode latched status, cleared on read
0 = No transition from Constant Power to Constant Current detected
1 = Transition from Constant Power to Constant Current detected
1
CP_TO_CV_INT
R
0
Constant Power Mode to Constant Voltage Mode latched status, cleared on read
0 = No transition from Constant Power to Constant Voltage detected
1 = Transition from Constant Power to Constant Voltage detected
0
CV_TO_CP_INT
R
0
Constant Voltage Mode to Constant Power Mode latched status, cleared on read
0 = No transition from Constant Voltage to Constant Power detected
1 = Transition from Constant Voltage to Constant Power detected